Application : Pharmaceutical, Chemical and Food Industry: Reactor cryogenic unit, food-grade water chiller, air purification and regulation unit. It can accurately control temperature, improve product qualification rate and improve production efficiency. The reactor cryogenic unit is used to maintain the low temperature conditions required for the chemical reaction in the reactor. It is used for rapid cooling of raw materials, preventing material deterioration, low temperature crystallization...


Product Detail

Product Tags

Application :
Pharmaceutical, Chemical and Food Industry: Reactor cryogenic unit, food-grade water chiller, air purification and regulation unit. It can accurately control temperature, improve product qualification rate and improve production efficiency.
The reactor cryogenic unit is used to maintain the low temperature conditions required for the chemical reaction in the reactor. It is used for rapid cooling of raw materials, preventing material deterioration, low temperature crystallization, low temperature extraction, low temperature synthesis. The temperature range can be adjusted from 30 degrees to 110 degrees below zero, and the refrigeration range is 10-1000KW.
Food-grade chiller: After food is processed at high temperature, in order to pack quickly, it is necessary to make the temperature of food meet the packaging requirements. Industrial chillers are used to quickly cool the processed food to meet the requirements. In addition, in the process of food fermentation, different temperatures are also needed to stabilize the need for fermentation, so in order to ensure the quality of fermentation products, it is necessary to accurately control the temperature by water coolers.
Air purification and regulation unit: In the pharmaceutical and chemical industry, dust-free workshop and other occasions, the temperature, humidity and cleanliness requirements of the use environment are controlled within a certain range. The surface cooler of water chiller is designed and integrated with air purification device. It can control the temperature of large area environment and realize the purification, dust removal, disinfection and sterilization of large area environment. Generally, centralized air supply is adopted. It has the function of constant temperature and humidity and is more convenient and practical than common central air conditioning.
1. International well-known compressors: adopt world-famous twin-screw compressor series, high efficiency 5:6 asymmetric screw tooth profile and advanced linear design. The machine has simple structure, only one tenth of the number of parts of piston compressor, less vulnerable parts, no suction and exhaust valves, no expansion process, large single-stage pressure ratio, insensitive to hydraulic shock. Built-in high-efficiency oil separator, the amount of oil brought out by exhaust is less than 1.5%. It can effectively improve the heat transfer efficiency of the two exchangers and save energy and durable. Efficient energy control can automatically realize 10%-100% grading or stepless energy regulation according to load variation. Through multi-head coordination and PLC control technology, the water-cooled screw chiller can achieve the best energy efficiency ratio at full or partial load, significantly reducing your operating costs.
2. Shell-and-tube condenser: using high-efficiency external threaded copper tubes, using the latest CAD/CAM design and processing technology, with CNC processing center production, corresponding to heat dissipation, water flow rate, scaling coefficient, calculating the effective heat transfer area, leaving 5-10% surplus; both end caps are easy to disassemble, easy to maintain;
3. Evaporator: Effective anticorrosive evaporator with ethylene glycol and brine as heat transfer medium, high efficiency and long service life.
4. Control system: industrial-level centralized control system, PIC controller, 7-inch touch color screen, all-Chinese operation interface, menu prompt easy to operate, can view the operation status of the unit at any time, adjust the working mode, accurately control the matching of refrigeration capacity and cooling load of the unit, ensure that the unit runs with the best efficiency and reduce operating costs. Internal integration of water flow, low temperature, high and low pressure, anti-freezing, reverse phase, delay start, overload, over-temperature, oil pressure difference and other security protection functions.
5. Accurate control can control the temperature in the range of (+1). It is easy to operate, safe and reliable.
6. The unit has beautiful appearance, neat layout, compact structure, small occupied area, and is convenient for inspection and maintenance.

Parameters of screw chiller

Model

LGSJ-100K

LGSJ-140K

LGSJ-180K

LGSJ-200K

LGSJ-230K

LGSJ-260K

LGSJ-300K

LGSJ-310K

LGSJ-340K

LGSJ-370K

Refrigerating capacity

KW/h

86

119

156

168

209

225

265

280

312

336

KCal/h

73947

102322

134136

144454

179708

193465

227859

240757

268272

288908

Btu/h

293515

409556

535836

573378

713310

767918

907850

955631

1064846

1146758

Power Supply

3P-380V/50Hz

Throttling mode

Electronic Expansion Valve/Thermal Expansion Valve

Input power KW

22.9

30

38

41.9

50

54.8

62.1

66.1

72.1

78.2

Energy efficiency ratio

3.755

3.96

4.1

4.01

4.18

4.11

4.26

4.23

4.32

4.29

Compressor

type

Semi-closed twin-screw compressor

Startup mode

Y-△/△-△

Unloading type

0-25%-50%-75%-100%/0-33%-66%-100%

condenser

structural style

External Thread and Shell-and-Tube Type in Colleges and Universities

cooling water temperature

Influent 30℃/effluent 35℃

Cooling water flow(m³/h)

20

26

35

38

47

50

60

63

70

75

Inlet and outlet pipe diameter(DN)

65

65

80

80

100

100

100

100

100

125

Fouling coefficient

0.088㎡*℃/Kw

evaporator

structural style

High Efficiency Internal Thread、Shell and Tube Type

Freezing water temperature

Influent 12℃/effluent 7℃

Frozen water flow(m³/h)

15

20

27

29

36

39

46

48

54

58

Inlet and outlet pipe diameter (DN)

65

65

80

80

100

100

100

100

100

125

Fouling coefficient

0.018㎡*℃/Kw

Protection mode

Leakage protection, reverse protection of power supply, phase absence protection, motor overcurrent protection, compressor overheating protection, system pressure abnormal protection, oil level abnormal protection, exhaust temperature abnormal protection, system water shortage protection and so on.

SIZE CM

L

225

225

244

246

290

290

290

290

290

295

W

900

900

950

100

100

110

120

120

120

120

H

130

130

140

145

150

150

156

156

156

156

WEIHGT

KG

950

1000

1300

1450

1700

1750

2150

2200

2250

2300

 

Parameters of screw chiller

Model

LGSJ-410K

LGSJ-470K

LGSJ-510K

LGSJ-550K

LGSJ-580K

LGSJ-620K

LGSJ-710K

LGSJ-790K

LGSJ-830K

LGSJ-930K

Refrigerating capacity

KW/h

365

444

464

513

556

577

672

724

788

889

KCal/h

313844

381771

398968

441101

478074

496131

577816

622528

677558

764402

Btu/h

1245734

1515358

1583618

1750853

1897611

1969283

2293515

2470990

2689420

3034130

Power Supply

3P-380V/50Hz

Throttling mode

Electronic Expansion Valve/Thermal Expansion Valve

Input power KW

86.2

103.2

105.6

118.8

127.1

133

151.6

163.5

178.6

201.8

Energy efficiency ratio

4.23

4.3

4.39

4.31

4.37

4.33

4.43

4.42

4.41

4.4

Compressor

type

Semi-closed twin-screw compressor

Startup mode

Y-△/△-△

Unloading type

0-25%-50%-75%-100%/0-33%-66%-100%

condenser

structural style

External Thread and Shell-and-Tube Type in Colleges and Universities

cooling water temperature

Influent 30℃/effluent 35℃

Cooling water flow(m³/h)

82

100

104

115

125

129

150

162

176

200

Inlet and outlet pipe diameter(DN)

125

125

125

150

150

150

150

150

200

200

Fouling coefficient

0.088㎡*℃/Kw

evaporator

structural style

High Efficiency Internal Thread、Shell and Tube Type

Freezing water temperature

Influent 12℃/effluent 7℃

Frozen water flow(m³/h)

63

76

80

88

96

99

116

125

136

153

Inlet and outlet pipe diameter (DN)

125

125

125

150

150

150

150

150

200

200

Fouling coefficient

0.018㎡*℃/Kw

Protection mode

Leakage protection, reverse protection of power supply, phase absence protection, motor overcurrent protection, compressor overheating protection, system pressure abnormal protection, oil level abnormal protection, exhaust temperature abnormal protection, system water shortage protection and so on.

SIZE(CM)

L

330

330

330

330

335

335

336

360

365

392

W

120

120

120

120

130

130

130

160

160

140

H

165

172

172

180

185

185

188

200

200

200

WEIHGT

KG

2480

2750

2950

3100

3280

3450

400

4380

4450

4600

Note: Above parameters: evaporation temperature 2℃, condensation temperature 40℃.

Note:

1) above the parameter value conditions are: evaporation temperature -20℃, condensation temperature 40 ℃.
2) the above parameters is a standard water-cooled chiller technical parameters.
3) Statement: constantly updated technology, the above parameters are subject to change without notice.
After-sales service is solemnly committed to the principle of improving customer satisfaction:
1. The company establishes complete data files for the products sold, and has a professional and capable after-sales team to provide all-round tracking service and excellent after-sales service.
2. According to the actual needs of users to provide a complete use and design plan from equipment selection to site design, engineering installation, after-sales service as a whole.
3. At any time to solve the task technical problems for you, the company will regularly visit the status of equipment use; after-sales service team will periodically inspect, prevent trouble before it happens, so that you truly experience excellent service quality.
4. Carry out timely after-sales maintenance and maintenance services in strict accordance with the after-sales service terms. The free warranty period is one year, and the maintenance of spare parts is provided free of charge during the warranty period.
5. Lifelong maintenance, equipment failure after the expiration of the warranty period, damaged parts are only charged at factory price.
 


  • Previous:
  • Next:

  • Related Products