Lowest Price for Water To Water Heat Pump - Reactor cryogenic unit – Sunvi
Lowest Price for Water To Water Heat Pump - Reactor cryogenic unit – Sunvi Detail:
Application :
Pharmaceutical, Chemical and Food Industry: Reactor cryogenic unit, food-grade water chiller, air purification and regulation unit. It can accurately control temperature, improve product qualification rate and improve production efficiency.
The reactor cryogenic unit is used to maintain the low temperature conditions required for the chemical reaction in the reactor. It is used for rapid cooling of raw materials, preventing material deterioration, low temperature crystallization, low temperature extraction, low temperature synthesis. The temperature range can be adjusted from 30 degrees to 110 degrees below zero, and the refrigeration range is 10-1000KW.
Food-grade chiller: After food is processed at high temperature, in order to pack quickly, it is necessary to make the temperature of food meet the packaging requirements. Industrial chillers are used to quickly cool the processed food to meet the requirements. In addition, in the process of food fermentation, different temperatures are also needed to stabilize the need for fermentation, so in order to ensure the quality of fermentation products, it is necessary to accurately control the temperature by water coolers.
Air purification and regulation unit: In the pharmaceutical and chemical industry, dust-free workshop and other occasions, the temperature, humidity and cleanliness requirements of the use environment are controlled within a certain range. The surface cooler of water chiller is designed and integrated with air purification device. It can control the temperature of large area environment and realize the purification, dust removal, disinfection and sterilization of large area environment. Generally, centralized air supply is adopted. It has the function of constant temperature and humidity and is more convenient and practical than common central air conditioning.
1. International well-known compressors: adopt world-famous twin-screw compressor series, high efficiency 5:6 asymmetric screw tooth profile and advanced linear design. The machine has simple structure, only one tenth of the number of parts of piston compressor, less vulnerable parts, no suction and exhaust valves, no expansion process, large single-stage pressure ratio, insensitive to hydraulic shock. Built-in high-efficiency oil separator, the amount of oil brought out by exhaust is less than 1.5%. It can effectively improve the heat transfer efficiency of the two exchangers and save energy and durable. Efficient energy control can automatically realize 10%-100% grading or stepless energy regulation according to load variation. Through multi-head coordination and PLC control technology, the water-cooled screw chiller can achieve the best energy efficiency ratio at full or partial load, significantly reducing your operating costs.
2. Shell-and-tube condenser: using high-efficiency external threaded copper tubes, using the latest CAD/CAM design and processing technology, with CNC processing center production, corresponding to heat dissipation, water flow rate, scaling coefficient, calculating the effective heat transfer area, leaving 5-10% surplus; both end caps are easy to disassemble, easy to maintain;
3. Evaporator: Effective anticorrosive evaporator with ethylene glycol and brine as heat transfer medium, high efficiency and long service life.
4. Control system: industrial-level centralized control system, PIC controller, 7-inch touch color screen, all-Chinese operation interface, menu prompt easy to operate, can view the operation status of the unit at any time, adjust the working mode, accurately control the matching of refrigeration capacity and cooling load of the unit, ensure that the unit runs with the best efficiency and reduce operating costs. Internal integration of water flow, low temperature, high and low pressure, anti-freezing, reverse phase, delay start, overload, over-temperature, oil pressure difference and other security protection functions.
5. Accurate control can control the temperature in the range of (+1). It is easy to operate, safe and reliable.
6. The unit has beautiful appearance, neat layout, compact structure, small occupied area, and is convenient for inspection and maintenance.
Parameters of screw chiller |
|||||||||||
Model |
LGSJ-100K |
LGSJ-140K |
LGSJ-180K |
LGSJ-200K |
LGSJ-230K |
LGSJ-260K |
LGSJ-300K |
LGSJ-310K |
LGSJ-340K |
LGSJ-370K |
|
Refrigerating capacity |
KW/h |
86 |
119 |
156 |
168 |
209 |
225 |
265 |
280 |
312 |
336 |
KCal/h |
73947 |
102322 |
134136 |
144454 |
179708 |
193465 |
227859 |
240757 |
268272 |
288908 |
|
Btu/h |
293515 |
409556 |
535836 |
573378 |
713310 |
767918 |
907850 |
955631 |
1064846 |
1146758 |
|
Power Supply |
3P-380V/50Hz |
||||||||||
Throttling mode |
Electronic Expansion Valve/Thermal Expansion Valve |
||||||||||
Input power KW |
22.9 |
30 |
38 |
41.9 |
50 |
54.8 |
62.1 |
66.1 |
72.1 |
78.2 |
|
Energy efficiency ratio |
3.755 |
3.96 |
4.1 |
4.01 |
4.18 |
4.11 |
4.26 |
4.23 |
4.32 |
4.29 |
|
Compressor |
type |
Semi-closed twin-screw compressor |
|||||||||
Startup mode |
Y-△/△-△ |
||||||||||
Unloading type |
0-25%-50%-75%-100%/0-33%-66%-100% |
||||||||||
condenser |
structural style |
External Thread and Shell-and-Tube Type in Colleges and Universities |
|||||||||
cooling water temperature |
Influent 30℃/effluent 35℃ |
||||||||||
Cooling water flow(m³/h) |
20 |
26 |
35 |
38 |
47 |
50 |
60 |
63 |
70 |
75 |
|
Inlet and outlet pipe diameter(DN) |
65 |
65 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
125 |
|
Fouling coefficient |
0.088㎡*℃/Kw |
||||||||||
evaporator |
structural style |
High Efficiency Internal Thread、Shell and Tube Type |
|||||||||
Freezing water temperature |
Influent 12℃/effluent 7℃ |
||||||||||
Frozen water flow(m³/h) |
15 |
20 |
27 |
29 |
36 |
39 |
46 |
48 |
54 |
58 |
|
Inlet and outlet pipe diameter (DN) |
65 |
65 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
125 |
|
Fouling coefficient |
0.018㎡*℃/Kw |
||||||||||
Protection mode |
Leakage protection, reverse protection of power supply, phase absence protection, motor overcurrent protection, compressor overheating protection, system pressure abnormal protection, oil level abnormal protection, exhaust temperature abnormal protection, system water shortage protection and so on. |
||||||||||
SIZE CM |
L |
225 |
225 |
244 |
246 |
290 |
290 |
290 |
290 |
290 |
295 |
W |
900 |
900 |
950 |
100 |
100 |
110 |
120 |
120 |
120 |
120 |
|
H |
130 |
130 |
140 |
145 |
150 |
150 |
156 |
156 |
156 |
156 |
|
WEIHGT |
KG |
950 |
1000 |
1300 |
1450 |
1700 |
1750 |
2150 |
2200 |
2250 |
2300 |
Parameters of screw chiller |
|||||||||||
Model |
LGSJ-410K |
LGSJ-470K |
LGSJ-510K |
LGSJ-550K |
LGSJ-580K |
LGSJ-620K |
LGSJ-710K |
LGSJ-790K |
LGSJ-830K |
LGSJ-930K |
|
Refrigerating capacity |
KW/h |
365 |
444 |
464 |
513 |
556 |
577 |
672 |
724 |
788 |
889 |
KCal/h |
313844 |
381771 |
398968 |
441101 |
478074 |
496131 |
577816 |
622528 |
677558 |
764402 |
|
Btu/h |
1245734 |
1515358 |
1583618 |
1750853 |
1897611 |
1969283 |
2293515 |
2470990 |
2689420 |
3034130 |
|
Power Supply |
3P-380V/50Hz |
||||||||||
Throttling mode |
Electronic Expansion Valve/Thermal Expansion Valve |
||||||||||
Input power KW |
86.2 |
103.2 |
105.6 |
118.8 |
127.1 |
133 |
151.6 |
163.5 |
178.6 |
201.8 |
|
Energy efficiency ratio |
4.23 |
4.3 |
4.39 |
4.31 |
4.37 |
4.33 |
4.43 |
4.42 |
4.41 |
4.4 |
|
Compressor |
type |
Semi-closed twin-screw compressor |
|||||||||
Startup mode |
Y-△/△-△ |
||||||||||
Unloading type |
0-25%-50%-75%-100%/0-33%-66%-100% |
||||||||||
condenser |
structural style |
External Thread and Shell-and-Tube Type in Colleges and Universities |
|||||||||
cooling water temperature |
Influent 30℃/effluent 35℃ |
||||||||||
Cooling water flow(m³/h) |
82 |
100 |
104 |
115 |
125 |
129 |
150 |
162 |
176 |
200 |
|
Inlet and outlet pipe diameter(DN) |
125 |
125 |
125 |
150 |
150 |
150 |
150 |
150 |
200 |
200 |
|
Fouling coefficient |
0.088㎡*℃/Kw |
||||||||||
evaporator |
structural style |
High Efficiency Internal Thread、Shell and Tube Type |
|||||||||
Freezing water temperature |
Influent 12℃/effluent 7℃ |
||||||||||
Frozen water flow(m³/h) |
63 |
76 |
80 |
88 |
96 |
99 |
116 |
125 |
136 |
153 |
|
Inlet and outlet pipe diameter (DN) |
125 |
125 |
125 |
150 |
150 |
150 |
150 |
150 |
200 |
200 |
|
Fouling coefficient |
0.018㎡*℃/Kw |
||||||||||
Protection mode |
Leakage protection, reverse protection of power supply, phase absence protection, motor overcurrent protection, compressor overheating protection, system pressure abnormal protection, oil level abnormal protection, exhaust temperature abnormal protection, system water shortage protection and so on. |
||||||||||
SIZE(CM) |
L |
330 |
330 |
330 |
330 |
335 |
335 |
336 |
360 |
365 |
392 |
W |
120 |
120 |
120 |
120 |
130 |
130 |
130 |
160 |
160 |
140 |
|
H |
165 |
172 |
172 |
180 |
185 |
185 |
188 |
200 |
200 |
200 |
|
WEIHGT |
KG |
2480 |
2750 |
2950 |
3100 |
3280 |
3450 |
400 |
4380 |
4450 |
4600 |
Note: Above parameters: evaporation temperature 2℃, condensation temperature 40℃. |
Note:
1) above the parameter value conditions are: evaporation temperature -20℃, condensation temperature 40 ℃.
2) the above parameters is a standard water-cooled chiller technical parameters.
3) Statement: constantly updated technology, the above parameters are subject to change without notice.
After-sales service is solemnly committed to the principle of improving customer satisfaction:
1. The company establishes complete data files for the products sold, and has a professional and capable after-sales team to provide all-round tracking service and excellent after-sales service.
2. According to the actual needs of users to provide a complete use and design plan from equipment selection to site design, engineering installation, after-sales service as a whole.
3. At any time to solve the task technical problems for you, the company will regularly visit the status of equipment use; after-sales service team will periodically inspect, prevent trouble before it happens, so that you truly experience excellent service quality.
4. Carry out timely after-sales maintenance and maintenance services in strict accordance with the after-sales service terms. The free warranty period is one year, and the maintenance of spare parts is provided free of charge during the warranty period.
5. Lifelong maintenance, equipment failure after the expiration of the warranty period, damaged parts are only charged at factory price.
Product detail pictures:


Related Product Guide:
Global Ultra-Low Temperature Air Source Heat Pump Market, Trend, CAGR Status, Growth, Analysis and Forecast (2019 – 2024) | Multifunctional Heat Pump
Johnson Controls Brings Innovative Technologies to Data Centers My Account Sign In Register ico-supplier ico-white-paper-case-study ico-product ico-cad | Air To Water Heatpump
We are going to dedicate ourselves to providing our esteemed buyers together with the most enthusiastically thoughtful products and services for Lowest Price for Water To Water Heat Pump - Reactor cryogenic unit – Sunvi, The product will supply to all over the world, such as: Netherlands, Costa Rica, Guatemala, Our mission is "Provide Goods with Reliable Quality and Reasonable Prices". We welcome customers from every corner of the world to contact us for future business relationships and achieving mutual success!

Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!