We help the world growing since 2015

Cryogenic ethylene glycol (brine) unit

Short Description:

Application : Cryogenic water chiller is a special refrigeration equipment which provides cryogenic refrigerant. It is suitable for various occasions with medium and low temperature cold source requirements. It is widely used as a process cold source for non-ferrous metallurgy, chemical and pharmaceutical intermediates, petrochemical industry, grain and oil, beverage and food, machinery, medicine, electronics, air separation and other production and processing. Cryogenic water chiller is a ne...


Product Detail

Product Tags

Application :
Cryogenic water chiller is a special refrigeration equipment which provides cryogenic refrigerant. It is suitable for various occasions with medium and low temperature cold source requirements. It is widely used as a process cold source for non-ferrous metallurgy, chemical and pharmaceutical intermediates, petrochemical industry, grain and oil, beverage and food, machinery, medicine, electronics, air separation and other production and processing.
Cryogenic water chiller is a new generation of cryogenic equipment specially designed for special industry requirements. Its temperature range can be adjusted from 30 degrees to 60 degrees below zero. The refrigeration range is 10 – 1000KW. The cryogenic chillers are divided into three series of water supply units with high, medium and low temperature according to the cooling range.
1. Standard chiller: It can provide 3-35 ~C chilled water, or use ethylene glycol solution as refrigerant. It can provide -5-5 ~5 ~C process chilled water solution. It can be used as the process cold source for ice storage, low temperature air supply, central air conditioning and other production processes. At the same time, according to the user’s requirements, the unit can be specially designed to provide screw chillers with large temperature difference.
2. Medium temperature chiller: the outlet water temperature is – 5 ~45 C, using imported semi-closed screw compressor unit (with economizer); low temperature ethylene glycol solution or saline solution can be provided from – 5 ~45%. It can be used as a cold source for chemical industry, medicine, cold storage, ice rink and other processes.
3. Cryogenic screw chiller: The effluent temperature is – 45 ~110 C, which can provide – 45 ~110 ~alcohol or dichloromethane solution frozen water. Using binary cascade refrigeration system or ternary cascade refrigeration system, the operation is stable and the energy efficiency ratio is high.

Parameters of screw chiller

Model

LGSJ-100K

LGSJ-140K

LGSJ-180K

LGSJ-200K

LGSJ-230K

LGSJ-260K

LGSJ-300K

LGSJ-310K

LGSJ-340K

LGSJ-370K

Refrigerating capacity

KW/h

86

119

156

168

209

225

265

280

312

336

KCal/h

73947

102322

134136

144454

179708

193465

227859

240757

268272

288908

Btu/h

293515

409556

535836

573378

713310

767918

907850

955631

1064846

1146758

Power Supply

3P-380V/50Hz

Throttling mode

Electronic Expansion Valve/Thermal Expansion Valve

Input power KW

22.9

30

38

41.9

50

54.8

62.1

66.1

72.1

78.2

Energy efficiency ratio

3.755

3.96

4.1

4.01

4.18

4.11

4.26

4.23

4.32

4.29

Compressor

type

Semi-closed twin-screw compressor

Startup mode

Y-△/△-△

Unloading type

0-25%-50%-75%-100%/0-33%-66%-100%

condenser

structural style

External Thread and Shell-and-Tube Type in Colleges and Universities

cooling water temperature

Influent 30℃/effluent 35℃

Cooling water flow(m³/h)

20

26

35

38

47

50

60

63

70

75

Inlet and outlet pipe diameter(DN)

65

65

80

80

100

100

100

100

100

125

Fouling coefficient

0.088㎡*℃/Kw

evaporator

structural style

High Efficiency Internal Thread、Shell and Tube Type

Freezing water temperature

Influent 12℃/effluent 7℃

Frozen water flow(m³/h)

15

20

27

29

36

39

46

48

54

58

Inlet and outlet pipe diameter (DN)

65

65

80

80

100

100

100

100

100

125

Fouling coefficient

0.018㎡*℃/Kw

Protection mode

Leakage protection, reverse protection of power supply, phase absence protection, motor overcurrent protection, compressor overheating protection, system pressure abnormal protection, oil level abnormal protection, exhaust temperature abnormal protection, system water shortage protection and so on.

SIZE CM

L

225

225

244

246

290

290

290

290

290

295

W

900

900

950

100

100

110

120

120

120

120

H

130

130

140

145

150

150

156

156

156

156

WEIHGT

KG

950

1000

1300

1450

1700

1750

2150

2200

2250

2300

 

Parameters of screw chiller

Model

LGSJ-410K

LGSJ-470K

LGSJ-510K

LGSJ-550K

LGSJ-580K

LGSJ-620K

LGSJ-710K

LGSJ-790K

LGSJ-830K

LGSJ-930K

Refrigerating capacity

KW/h

365

444

464

513

556

577

672

724

788

889

KCal/h

313844

381771

398968

441101

478074

496131

577816

622528

677558

764402

Btu/h

1245734

1515358

1583618

1750853

1897611

1969283

2293515

2470990

2689420

3034130

Power Supply

3P-380V/50Hz

Throttling mode

Electronic Expansion Valve/Thermal Expansion Valve

Input power KW

86.2

103.2

105.6

118.8

127.1

133

151.6

163.5

178.6

201.8

Energy efficiency ratio

4.23

4.3

4.39

4.31

4.37

4.33

4.43

4.42

4.41

4.4

Compressor

type

Semi-closed twin-screw compressor

Startup mode

Y-△/△-△

Unloading type

0-25%-50%-75%-100%/0-33%-66%-100%

condenser

structural style

External Thread and Shell-and-Tube Type in Colleges and Universities

cooling water temperature

Influent 30℃/effluent 35℃

Cooling water flow(m³/h)

82

100

104

115

125

129

150

162

176

200

Inlet and outlet pipe diameter(DN)

125

125

125

150

150

150

150

150

200

200

Fouling coefficient

0.088㎡*℃/Kw

evaporator

structural style

High Efficiency Internal Thread、Shell and Tube Type

Freezing water temperature

Influent 12℃/effluent 7℃

Frozen water flow(m³/h)

63

76

80

88

96

99

116

125

136

153

Inlet and outlet pipe diameter (DN)

125

125

125

150

150

150

150

150

200

200

Fouling coefficient

0.018㎡*℃/Kw

Protection mode

Leakage protection, reverse protection of power supply, phase absence protection, motor overcurrent protection, compressor overheating protection, system pressure abnormal protection, oil level abnormal protection, exhaust temperature abnormal protection, system water shortage protection and so on.

SIZE(CM)

L

330

330

330

330

335

335

336

360

365

392

W

120

120

120

120

130

130

130

160

160

140

H

165

172

172

180

185

185

188

200

200

200

WEIHGT

KG

2480

2750

2950

3100

3280

3450

400

4380

4450

4600

Note: Above parameters: evaporation temperature 2℃, condensation temperature 40℃.

Note:
1) above the parameter value conditions are: evaporation temperature -28℃, condensation temperature 40 ℃.
2) the above parameters is a standard water-cooled chiller technical parameters.
3) Statement: constantly updated technology, the above parameters are subject to change without notice.
After-sales service is solemnly committed to the principle of improving customer satisfaction:
1. The company establishes complete data files for the products sold, and has a professional and capable after-sales team to provide all-round tracking service and excellent after-sales service.
2. According to the actual needs of users to provide a complete use and design plan from equipment selection to site design, engineering installation, after-sales service as a whole.
3. At any time to solve the task technical problems for you, the company will regularly visit the status of equipment use; after-sales service team will periodically inspect, prevent trouble before it happens, so that you truly experience excellent service quality.
4. Carry out timely after-sales maintenance and maintenance services in strict accordance with the after-sales service terms. The free warranty period is one year, and the maintenance of spare parts is provided free of charge during the warranty period.
5. Lifelong maintenance, equipment failure after the expiration of the warranty period, damaged parts are only charged at factory price.


  • Previous:
  • Next: